About the Maintenance of Steam BoilerⅠ

Porto

About the Maintenance of Steam BoilerⅠ

2016-04-07 08:28 190 Amy

About the Maintenance of Steam BoilerⅠ

1. The boiler water must be softened water treatment in line with the standard of water. Maintenance of the boiler must be cut off the power supply and must be pressure relief.
2. The daily use of the boiler must be sewage, in order to ensure that the water quality of the boiler clean.
3. Often check the transmission line, feed pump, control box, pressure switch box safety valve and other key components of the operating conditions, the abnormal find the reason and maintenance timely.
4. Boiler should conduct an internal cleaning and cleaning work every six months or a year to ensure the efficiency and service life of the boiler.
5. The water level gauge to always keep clean, wash once a day, in order to ensure that the water level.
6. To prevent rusting failure, the safety valve to move the valve handle once daily, 
7. The boiler stops running time is longer, it should cut off power, at the same time, the boiler, the water in the pipeline to put the net, in case of freezing, rust phenomenon.
8. Regular heating pipe connection on the fastening screws and the flange.
9. Through the "listening, smelling, looking, touching" to do a good job in the control box of the normal maintenance work. If abnormal phenomenon should be immediately cut off the power supply and maintenance.